idslogosize2.jpg (6710 bytes)

seilogo.jpg (6164 bytes)

SEI Power

ISDN NT1 Racks and ISDN CPE Power

SEI is the world's leading supplier of power systems for ISDN-based customer premises equipment.  Their particular focus is the Customer Premise Equipment powering needs of digital Centrex telephony.

PoweRack Series

PoweRacks are specifically designed for the Lucent B-300 NT1, P-230 circuit card and D-300 12-pack.  Integrated NT1 caging, DC power, battery backup and cable distribution are assembled in a footprint as small as 19x14 inches.  Installation time is virtually eliminated!

The PoweRack is available in a variety of models depending on the number of phones, NT1 type and the battery backup time desired.

The PR300-U is an enhanced version of the PoweRack 300R.  This a premises powering unit that integrates NT1 caging, 48 volt DC power, and battery backup in a single unit for powering ISDN telephones and Lucent B-300 NT1's or equivalents.  The PR300-U is available in four models that house and power 12 to 48 NT1's and provide power for 24 to 96 phones in a multipoint mode.  In addition, the 24 and 72 line versions of the PR300 are field upgradeable by adding a 300R-U NT1 cage. The PoweRack 300-U can be either wall or rack mounted.  The small footprint and simple installation of the PR300-U allows a cost-effective installation without the requirement for punchdown blocks (an optional wiring harness is available to facilitate NT1 input cabling).  Battery holdover can be increased by adding external battery packs.  During extended periods of utility outage the batteries are protected from over-discharge by the built-in low voltage detector and disconnect circuit.  Remote monitoring is provided by a contact closure that can be interfaced to a remote alarm unit. seipr300family.jpg (60771 bytes)

Ordering Information

Model Description Dimensions 
(W" x D" x H")
PR300-24-U PoweRack with 1 NT1 card cage
and 2.5 AmpHr battery (2 hour holdover)
19 x 6 x 12
PR300-48-U PoweRack with 2 NT1 card cages 
and 2.5 AmpHr battery (1 hour holdover)
19 x 6 x 17
PR300-72-U PoweRack with 3 NT1 card cages 
and 8 AmpHr battery (2 hour holdover)
19 x 6 x 30
PR300-96-U PoweRack with 4 NT1 card cages
and 8 AmpHr battery (1 hour holdover)
19 x 6 x 35

Options

RA Remote alarm unit 2.5 x 4 x 1
300R-U Additional twelve position NT1 rack 19 x 5 x 5.25
BP2 Additional 2.5 AmpHr battery pack (for the PR300-24-U and PR300-48-U) 19 x 5 x 7
BP8 Additional 8 AmpHr battery pack (for the PR300-72-U and PR300-96-U) 19 x 5 x 7
NT1B-300 Lucent B-300 NT1 with multipoint capability
G-B300 Lucent-compatible NT1 sub-assembled in USA with multipoint capability 

Technical Specifications

Electrical Environmental
Universal Input (90-265 VAC)
Frequency 47-440 Hz
Output Voltage 42-56 VDC
Operating 0 deg C to +50 deg C
Storage -25 deg C to +60 deg C
Humidity 95% non-condensing

Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C.
NT1 Compatibility Standards
Lucent NT1B-300 UL 1012

 

The PR230 is a premises powering unit that integrates NT1 caging, 48 volt DC power, and battery backup in a single unit for powering ISDN telephones and Lucent P-230 circuit card NT1's or equivalents. 

The PR230 is available in two configurations.  The PR230-24 will house and power up to 12 P-230 NT1's and provide power for up to 24 phones in a multipoint mode.  the PR230-48 adds additional caging to house and power a total of 24 NT1's with power for 48 multipoint phones.  Note that the PR230-24 can be field upgraded to PR230-48 capacity via an SEI 230R NT1 cage.

For both PR230 models output distribution is accomplished using standard 50 pin amphenol connectors which eliminate the need to use punchdown blocks.  All power lines to the terminals and NT1's are protected by solid state thermal fusing.  Dual load-sharing rectifiers offer redundancy, while additional external battery packs can be added at any time for increased standby time.  During extended periods of utility outage the batteries are protected from over-discharge by the built-in low voltage detector and disconnect circuit.  Remote monitoring is provided by a contact closure that can be interfaced to a remote alarm unit.

The PR230-24 can be utilized to provide power to legacy NT1 cages such as the Lucent NT1M-210.  Additionally, a stand-alone 230R expansion cage may be powered by third party powering units such as the Lucent 1145.  All PR series units are mountable either on a wall or on 19" racks.  Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number).

seipr230family.jpg (55532 bytes)

Ordering Information

Model # Description Dimensions
(W" x D" x H")
PR230-24 PoweRack with 1 NT1 card cage
and 2.5 AmpHr battery (2 hour holdover)
19 x 7.5 x 7
PR230-48 PoweRack with 2 NT1 card cages
and 2.5 AmpHr battery (1 hour holdover)
19 x 7.5 x 14

Options

230R Field Installable P-230 NT1 cage 19 x 7.5 x 7
RA Remote alarm unit 2.5 x 4 x 1
BP2 Additional 2.5 AmpHr battery pack 19 x 5 x 7
NT1P-230 Lucent P-230 circuit-card NT1 with multipoint capability
G-P230 Lucent-compatible NT1 sub-assembled in USA with multipoint capability

Technical Specifications

Electrical Environmental
Universal Input (90-265 VAC)
Frequency 47-440 Hz
Output Voltage 37-48 VDC
Operating 0 deg C to +50 deg C
Storage -25 deg C to +60 deg C
Humidity 95% non-condensing

Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C.
NT1 Compatibility Standards
Lucent NT1P-230 UL 1950, CSA 950, FCC A 

 

The PR96 is a premises powering unit that integrates NT1 caging, 48 volt DC power, and battery backup in a single unit for powering ISDN telephones and Lucent P-230 circuit card NT1's or equivalents.  The PR96 will house and power up to 48 P-230 NT1's and provide power for up to 96 phones in a multipoint mode.  Distribution is accomplished using standard 50 pin amphenol connectors which eliminate the need to use punchdown blocks.  All power lines to the terminals and NT1's are protected by solid state thermal fusing.  Additional external battery packs can be added at any time for increased standby time.  During extended periods of utility outage the batteries are protected from over-discharge by the built-in low voltage detector and disconnect circuit.  Remote monitoring is provided by a contact closure that can be interfaced to a remote alarm unit.

All PR series units are mountable either on a wall or on 19" racks.  Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number).

seipr96.jpg (50299 bytes)

Ordering Information

Model # Description Dimensions
(W" x D" x H")
PR96-8 PoweRack with internal 8 AmpHr battery pack (1 hour holdover) 19 x 8 x 19

Options

RA Remote alarm unit 2.5 x 4 x 1
BP8 Additional 8 AmpHr battery pack 19 x 5 x 7
NT1P-230 Lucent P-230 circuit-card NT1 with multipoint capability
G-P230 Lucent-compatible NT1 sub-assembled in USA with multipoint capability

Technical Specifications

Electrical Environmental
Universal Input (90-265 VAC)
Frequency 47-440 Hz
Output Voltage 42-56 VDC
Operating 0 deg C to +50 deg C
Storage -25 deg C to +60 deg C
Humidity 95% non-condensing

Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C.
NT1 Compatibility Standards
Lucent NT1P-230 UL 1012, CSA 234

 

The PR180 is a premises powering unit that integrates NT1 caging, dual 48 volt DC power supplies, and battery backup in a single unit for powering ISDN telephones and Lucent D-300 circuit card NT1's or equivalents.  The PR180 will house and power up to seven D-300 circuit cards and provide power for up to 180 phones in a multipoint mode.  Connections from the service provider are done with standard 25 pair amphenol connectors.   Distribution to the terminals is accomplished via standard 8-pin modular connectors.  All power to the terminals and NT1s are protected by solid state thermal fusing.  System operation is maintained after loss of commercial power by the companion BP180 battery packs, which slide on to the PR180 and fasten to the wall or rack.   During extended periods of utility outage the batteries are protected from over-discharge by the built-in low voltage detector and disconnect circuit.  The PR180 comes with an integrated battery test feature; remote monitoring is provided by a contact closure that can be interfaced to a remote alarm unit.

All PR series units are mountable either on a wall or on 19" racks.   Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number).

pr180pic.jpg (16865 bytes)

Ordering Information

Model # Description Dimensions
(W" x D" x H")
PR180-8 PoweRack with internal 8 AmpHr battery pack  19 x 9 x 28

Options

RA Remote alarm unit 2.5 x 4 x 1
BP180 Additional 8 AmpHr battery pack 19 x 9 x 5.25

Technical Specifications

Electrical Environmental

Universal Input (90-265 VAC)
Frequency 47-440 Hz
Output Voltage 42-56 VDC

Operating 0 deg C to +50 deg C
Storage -25 deg C to +60 deg C
Humidity 95% non-condensing

Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C.
NT1 Compatibility Standards
Lucent NT1D-300, Lucent NT1P-230 UL 1012, CSA 234

 

SEI's line of bulk or closet power provides 48 volt DC power to NT1's and phone sets.  The DP Series is characterized by a small footprint and easy installation.  Four models provide capability to power from 12 to 288 phones.  Battery backup provides up to 8 hours of holdover time.

To view the DP series Power Supplies go here:

DP Series

 

 

dpseries.jpg (29005 bytes)

 

Return to IDS Main Page

You are cordially invited to contact us regarding your ISDN needs and requirements.

Call us: Phone: (336) 299-4409 or Fax us: (336) 856-1342 or email: mail@idstech.com

We gladly accept creditcrds.jpg (1749 bytes)


IDS Technologies, Inc.
3714 Alliance Drive, Suite 105
Greensboro, North Carolina 27407 USA
IDS for ISDN Telephones
jakewink.gif (2520 bytes)
This Web Page created and maintained by the techno-folks at IDS Technologies, Inc.
All rights reserved © by System Engineering International