| The DP70 is a
bulk powering system that provides the necessary 48 volt DC current to power 12 NT1's and
24 multipoint ISDN phones. Integrated battery backup provides the user up to 8 hours
of uninterruptible power to insure continuous phone service in the event of local power
outages. Output distribution is provided by an
application specific distribution module on the side of the unit (50-pin amphenol and
6-pin modular connectors are standard) which incorporates overcurrent protection via
thermal fusing. During normal operation the telecommunication grade
rectifier/charger provides power to the load while maintaining the batteries in a fully
charged state. During extended periods of utility outage the batteries are protected
from over-discharge by the built-in low voltage detector and disconnect circuit.
Remote monitoring is provided by a contact closure that can be interfaced to a remote
alarm unit. All DP series units are mountable either on a wall or on 19" racks. Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number). |
![]() |
Ordering Information
| Model # | Description | Dimensions (W" x D" x H") |
|---|---|---|
| DP70-12-0 | DP70 with no battery holdover | 19 x 5 x 7 |
| DP70B-12-2 | DP70 with internal 2.5 AmpHr battery (2 hour holdover) | 19 x 5 x 7 |
| DP70B-12-8 | DP70 with internal 8 AmpHr battery (8 hour holdover) | 19 x 5 x 14 |
Options |
||
| RA | Remote alarm unit | 2.5 x 4 x 1 |
Technical Specifications
| Electrical | Environmental |
|---|---|
Universal
Input (90-265 VAC) |
Operating 0 deg C to +50 deg C Storage -55 deg C to +85 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
Standards |
|
UL 1012 |
|
| The DP140 is a
bulk powering system that provides the necessary 48 volt DC current to power 24 NT1's and
48 multipoint ISDN phones. Integrated battery backup provides the user up to 8 hours
of uninterruptible power to insure continuous phone service in the event of local power
outages. Output distribution is provided by an
application specific distribution module on the side of the unit (50-pin amphenol and
6-pin modular connectors are standard) which incorporates overcurrent protection via
thermal fusing. During normal operation the telecommunication grade
rectifier/charger provides power to the load while maintaining the batteries in a fully
charged state. During extended periods of utility outage the batteries are protected
from over-discharge by the built-in low voltage detector and disconnect circuit.
Remote monitoring is provided by a contact closure that can be interfaced to a remote
alarm unit. The DP140 is also available in a lower cost configuration (designated as the DP140A) which does not have a low voltage disconnect feature. All DP series units are mountable either on a wall or on 19" racks. Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number). |
![]() |
Ordering Information
| Model # | Description | Dimensions (W" x D" x H") |
|---|---|---|
| DP140A-24-0 | DP140 with no battery holdover, no low voltage disconnect | 19 x 5 x 7 |
| DP140-24-0 | DP140 with no battery holdover | 19 x 5 x 7 |
| DP140A-24-8 | DP140 with internal 8 AmpHr battery
(4 hour holdover) no low voltage disconnect |
19 x 5 x 14 |
| DP140B-24-8 | DP140 with internal 8 AmpHr battery (4 hour holdover) | 19 x 5 x 14 |
| DP140A-24-16 | DP140 with internal 8 AmpHr battery external 8 AmpHr battery pack (8 hour total holdover) no low voltage disconnect |
19 x 5 x 14 19 x 5 x 7 |
| DP140B-24-16 | DP140 with internal 8 AmpHr battery external 8 AmpHr battery pack (8 hour total holdover) |
19 x 5 x 14 19 x 5 x 7 |
Options |
||
| RA | Remote alarm unit | 2.5 x 4 x 1 |
Technical Specifications
| Electrical | Environmental |
|---|---|
Universal
Input (90-265 VAC) |
Operating 0 deg C to +50 deg C Storage -55 deg C to +85 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
Standards |
|
UL 1012 |
|
| The DP240 is a
bulk powering system that provides the necessary 48 volt DC current to power 48 NT1's and
96 multipoint ISDN phones. Integrated battery backup provides the user up to 8 hours
of uninterruptible power to insure continuous phone service in the event of local power
outages. Output distribution is provided by an application specific distribution
module on the side of the unit (50-pin amphenol and 6-pin modular connectors are standard)
which incorporates overcurrent protection via thermal fusing. During normal
operation the telecommunication grade rectifier/charger provides power to the load while
maintaining the batteries in a fully charged state. During extended periods of
utility outage the batteries are protected from over-discharge by the built-in low voltage
detector and disconnect circuit. Remote monitoring is provided by a contact closure
that can be interfaced to a remote alarm unit. All DP series units are mountable either on a wall or on 19" racks. Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number). |
![]() |
Ordering Information
| Model # | Description | Dimensions (W" x D" x H") |
|---|---|---|
| DP240-48-0 | DP240 with no battery holdover | 19 x 5 x 7 |
| DP240B-48-8 | DP240 with internal 8 AmpHr battery (2 hour holdover) | 19 x 5 x 14 |
| DP240B-48-16 | DP240 with internal 8 AmpHr battery external 8 AmpHr battery pack (4 hour total holdover) |
19 x 5 x 14 19 x 5 x 7 |
| DP240B-48-32 | DP240 with internal 8 AmpHr
battery external 8 AmpHr battery pack external 8 AmpHr battery pack (8 hour total holdover) |
19 x 5 x 14 19 x 5 x 7 19 x 5 x 7 |
Options |
||
| RA | Remote alarm unit | 2.5 x 4 x 1 |
Technical Specifications
| Electrical | Environmental |
|---|---|
Universal
Input (90-265 VAC) |
Operating 0 deg C to +50 deg C Storage -55 deg C to +85 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
Standards |
|
UL 1012 |
|
| The DP700 is a
bulk powering system that provides the necessary 48 volt DC current to power up to 144
NT1's and 288 multipoint ISDN phones along with battery backup. Output distribution
is provided by an application specific distribution module on the side of the unit (50-pin
amphenol and 6-pin modular connectors are standard) which incorporates overcurrent
protection via thermal fusing. During normal operation the telecommunication grade
rectifier/charger provides power to the load while maintaining the batteries in a fully
charged state. During extended periods of utility outage the batteries are protected
from over-discharge by the built-in low voltage detector and disconnect circuit.
Remote monitoring is provided by a contact closure that can be interfaced to a remote
alarm unit. All DP series units are mountable either on a wall or on 19" racks. Mounting brackets for 23" or 25" racks may be ordered as options (specify 23RM or 25RM after the model number). |
![]() |
Ordering Information
| Description | ||||
|---|---|---|---|---|
| Model # | NT1's | Multipoint Phones | Battery Reserve | Dimensions (W" x D" x H") |
| DP700-72-0 | 72 | 144 | None | 19 x 5 x 20 |
| DP700B-72-8 | 72 | 144 | 1 hour | 19 x 5 x 20 |
| DP700B-72-16 | 72 | 144 | 2 hours | 19 x 5 x 20 plus 19 x 5 x 7 (battery pack) |
| DP700B-72-24 | 72 | 144 | 4 hours | 19 x 5 x 20 plus plus battery tray/cabinet |
| DP700B-72-65 | 72 | 144 | 8 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700-96-0 | 96 | 192 | None | 19 x 5 x 20 |
| DP700B-96-16 | 96 | 192 | 1 hour | 19 x 5 x 20 plus 19 x 5 x 7 (battery pack) |
| DP700B-96-24 | 96 | 192 | 2 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-96-32 | 96 | 192 | 4 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-96-90 | 96 | 192 | 8 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700-120-0 | 120 | 240 | None | 19 x 5 x 20 |
| DP700B-120-16 | 120 | 240 | 1 hour | 19 x 5 x 20 plus 19 x 5 x 7 (battery pack) |
| DP700B-120-24 | 120 | 240 | 2 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-120-50 | 120 | 240 | 4 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-120-100 | 120 | 240 | 8 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700-144-0 | 144 | 288 | None | 19 x 5 x 20 |
| DP700B-144-16 | 144 | 288 | 1 hour | 19 x 5 x 20 plus 19 x 5 x 7 (battery pack) |
| DP700B-144-32 | 144 | 288 | 2 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-144-65 | 144 | 288 | 4 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
| DP700B-144-130 | 144 | 288 | 8 hours | 19 x 5 x 20 plus variable battery tray/cabinet |
Options |
||||
| RA | Remote alarm unit | 2.5 x 4 x 1 | ||
Technical Specifications
| Electrical | Environmental |
|---|---|
Universal
Input (90-265 VAC) |
Operating 0 deg C to +50 deg C Storage -55 deg C to +85 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
Standards |
|
UL 1012 |
|
You are cordially invited to contact us regarding your ISDN needs and requirements.
Call us: Phone: (336) 299-4409 or Fax us: (336) 856-1342 or email: mail@idstech.com We gladly acceptIDS Technologies, Inc. 3714 Alliance Drive, Suite 105 Greensboro, North Carolina 27407 USA
IDS for ISDN Telephones
This Web Page created and maintained by the techno-folks at IDS Technologies, Inc.