idslogosize2.jpg (6710 bytes)

lucent1.jpg (5979 bytes)

Lucent Technologies

Power Supplies and Peripheral ISDN Equipment


Please select your viewing choice from the menu below.

Local Power Supplies 1145B1/1146B1 Bulk Power Kit Sound Point Speakerphone

Lucent Technologies offers power sources ranging from individual desk units to bulk power supplies supporting as many as 48 NT1s and 96 ISDN telephones. See below for details.

Local Power Supplies

Lucent TIS1215A/B Power Supply

1215A Pwr Sups.jpg (28841 bytes) Pictured to the left are:

Left - old style 1215A CC 108000423 (No Longer Available)

Right - TIS1215B CC 300294485

The TIS1215B is a 120 VAC input, -48 VDC output Class 1 Power Supply. The TIS1215B employs an LED indicator that illuminates when the Power Supply is connected to power and has internal filtering to prevent electrical humming due to poor grounding. The Housing is a Wall Mount enclosure made from black color high impact plastic ABS and/or Noryl.

General specifications

Power Supply Type: Switiching Class 1 Power Supply
Connectors: Two Miniature 8-position jacks (RJ49)
                   Pin 7 of Out Jack = -48 VDC
                   Pin 8 of Out Jack = -48 VDC RTN
AC Input Voltage Range: 90 to 150 VAC
AC Input Frequency Range: 47 to 63 Hz
AC Input Current: 0.75A Max
Inrush Current: 15A @ 115 VAC, cold start
DC Output Voltage: -48 VDC +/- 1.5%
DC Output Current Range: 0 to 625 mA
Efficiency @ Full Load: 80% min @ 115VAC
DC Output Ripple & Noise: 250 mV p-p (max) @ 20MHz bandwidth
Line Regulation: +/- 1.0% 90 to 150 VAC
Load Regulation: +/- 1.5%
Wattage: 30 Watts
Dimensions: 3.75" x 2.6" x 2.9" (LxWxH)
Weight: 7 oz.
Overload Protection: Activated if AC input current > 0.85A
Over Voltage Protection: -60 VDC max
Shaort Circuit Protection: Continuous
Hold-up Time @ Full Load: 16 mSec min @ 115 VAC
Isolation - Input to Output: 3000 VAC 1 min
Isolation - Input to FG: 1500 VAC 1 min
Working Environment: +0 deg. C to +50 deg. C (32 deg. F to 122 deg. F), 5% to 95% RH, Non-Condensing
Storage Environment: -25 deg. C to +85 deg. C (-13 deg. F to 185 def. F), 5% to 95% RH, Non-Condensing
Safety Standard (approved): USL, CNL (UL mark and CUL mark)
EMI Standard (meets): FCC Part 15 Class B
The TIS1215A uses a three-prong plug to ensure proper grounding as well as stability when inserted into a flush-mount electrical jack. TIS1215A Rear.jpg (31018 bytes)

Lucent 1151A1 and 1151A2 Local Power Supply, 20 Watts

1151A.gif (21914 bytes)

Lucent Technologies introduces the world-class 1151A1 and 1151A2 48 V power units for ISDN telephones, network interfaces (NT1s), telephone adjuncts, and other customer premises equipment. Both units provide clean, regulated 48 V power to the load and can be either desktop or wall mounted. Additionally, the 1151A2 provides battery backup for up to 15 minutes at full load (20 W). Each unit comes complete with ac power and phone cords. Note: These have been discontinued by Lucent. Use TIS1215A for 1151A1 and PS102-4 for 1151A2.

Features
  • Universal ac input
  • 20 W of 48 V power
  • (2) RJ45 type connectors accept D8W modular plug cables
  • Operational LEDs:
    – Green, normal operation
    – Yellow, charging battery
  • Battery holdover with a 1.2 ampere hour battery

Input and Output Characteristics


  • Output:
    – 48 V at 20 W
    – Typical efficiency, 83% at full load
  • Input:
    – Voltage: 90 Vac to 132 Vac or 176 Vac to 264 Vac with auto ranging
    – Frequency: 60 Hz or 50 Hz
Product Attributes
  • Operating temperature 0 °C to 50 °C
  • For optimum battery life, 20 °C to 40 °C recommended


Standards


  • UL listed and CSA certified per UL 1950-CAN/CSA C22.2 No.950-95, Third Edition, Safety of Information Technology Equipment and approved per EN 60950 and EN 41003 with SELV rated output.
  • CE mark approved per EN 55022 Level B, EN 50082-1 and EN 60950.
  • Complies with Electromagnetic Interference – FCC Part 15 Subpart B, CDC and CISPR 22, EN 55022 Class B.
Selection Chart
Description Part No. Weight (Mounted)
1151A1 Power Kit 107787129 0.75 lb. (0.34 kg)
1151A2 Power Kit with 1.2 AH Battery 107787111 1.85 lb. (0.84 kg)
Typical Holdover Time at Room Temperature (25 °C)
Full Load (0.4 A) Half Load (0.2 A) Qtr. Load (0.1 A)
15 Minutes 40 Minutes 6–8 Hours

 


Lucent Technologies 1145B1/1146B1 Bulk Power Arrangement 225 W System with Battery

1145B1.gif (28095 bytes) The 1145 Power Supplies are No Longer Manufacturered and are very scarce. We offer them only if we have them in stock. We offer other solutions for Bulk Power needs. Contact us to discuss your installation power requirements.

This customer premises power arrangement provides uninterruptible power to 48 V loads such as ISDN telephones, network termination interfaces (NTIs), multiplexers, base stations, telephone adjuncts, and other customer premises equipment. When ac power is interrupted, batteries are automatically switched on to provide continuous power to the load. The optional distribution units provide up to 64 standard 110-type load connections with individual overcurrent protection and alarm LEDs. This compact, lightweight power arrangement is provided in kit form for easy wall or rack mounting.

Features
  • Universal ac input
  • Uninterrupted power to 48 V loads
  • Optional power distribution provides 32 or 64 standard 110-type load connections
  • Overcurrent protection and alarm LEDs on each output
  • Compact, lightweight, and modular in kit form
  • Easily wall or rack mounted
  • Operational alarms indicate system status
    – Green, normal operation
    – Yellow, battery charging
    – Red, operating on battery
  • External alarm capable with optional ac alarm cable
  • 2.5, 5.0, and 8.0 ampere hour batteries provide wide range of holdover time
  • Battery charging with constant voltage limitation and temperature compensation for extended battery life (typically 4 years)
Product Attributes
  • Operating temperature from 0 °C to 50 °C
  • For optimum battery life 20 °C to 40 °C recommended
  • Standards:
    UL listed per standard 1950 (without deviation)
    CSA certified per C22.2 No. 234
    – GS mark licensed per EN60950/DIN VDE 0805 and EN 41003/DIN VDE 0804T100
    – Complies with FCC Rules Part 15, CDC and CISPR 22 EN 55022 Class A



Input and Output Characteristics


  • Output:
    – 48 V at 225 W
    – 64 outputs with an average of 3.125 W each
    – Typical efficiency, 75% at full load
  • Input:
    – Voltage: 88 Vac to 132 Vac or 176 Vac to 264 Vac with auto line select
    – Frequency: 50 Hz or 60 Hz




1145connect.gif (11408 bytes)
Dimensions are in centimeters and (inches).

Selection Chart
Description Part No. Weight (Mounted)
64 Termination (Expanded) ISDN Kit w/2.5 Ah Battery 107581522 26 lb. (11.80 kg)
64 Termination (Expanded) ISDN Kit w/5.0 Ah Battery 107581514 36 lb. (16.33 kg)
64 Termination (Expanded) ISDN Kit w/8.0 Ah Battery 107581548 40 lb. (18.15 kg)
64 Termination (Expanded) ISDN Kit w/o Battery 107581530 11 lb. ( 4.99 kg)
32 Termination ISDN Kit w/2.5 Ah Battery 106448921 25 lb. (11.34 kg)
32 Termination ISDN Kit w/5.0 Ah Battery 106448939 35 lb. (15.88 kg)
32 Termination ISDN Kit w/8.0 Ah Battery 107334369 39 lb. (17.70 kg)
32 Termination ISDN Kit w/o Battery 106595606 10 lb. ( 4.54 kg)
Single Point of Load w/o Battery 106705288 10 lb. (4.54 kg)
Single Point of Load w/5.0 Ah Battery 106692999 34 lb (15.43 kg)
Single Point of Load w/8.0 Ah Battery 107659211 38 lb. (17.25 kg)
Optional Equipment
Rack Mounting Angle Bracket B10625-1 (19" L) 846786309 3 lb. (1.36 kg)
Rack Mounting Angle Bracket B10625-2 (23" L) 846786317 3 lb. (1.36 kg)
A/C Alarm Cable H 600-342 Group 6 (10' L) 847272481 1 lb. (0.45 kg)

 

Typical Holdover Time at Room Temperature (25 °C)
Battery Ah Full Load (4.16 A) Half Load (2.08 A)
2.5 Ah 15–20 minutes 50–60 minutes
5.0 Ah 40–50 minutes 110–120 minutes
8.0 Ah 90–100 minutes 220–240 minutes

Peripheral Equipment

 

Lucent Technologies SoundPoint DCP-2305-02900-001

soundpointdcp.jpg (37986 bytes)

 

Lucent Technologies now offers a full range of solutions for crystal clear conference calls with your Lucent 7400, 7500, 8400, and 8500 series of digital voice terminals. The SoundPoint systems are configured to work with each Definity or ISDN terminal - no need for a separate phone line!

SoundPoint delivers full-duplex business quality audioconferencing capability to your desktop or office.

SoundPoint may be used for conferencing alone or in a group, desktop video conferencing, or Internet Telephony.

Applications:

Full duplex audioconferencing for the desktop or office

Full duplex audioconferencing for videoconferences and Internet Telephony

 

Features:

Full-duplex digital phone adjunct for the desktop or office

Rare-earth neodymium speaker for light-weight, hi-fidelity, distortion free sound

Hypercardioid microphone for echo-free, 180° pick-up from up to 9 ft. away


returntolucent.jpg (4364 bytes)returnnavpanel.jpg (4680 bytes)

You are cordially invited to contact us regarding your ISDN needs and requirements.

Call us: Phone: (336) 299-4409 or Fax us: (336) 856-1342

We gladly accept creditcrds.jpg (1749 bytes)


IDS Technologies, Inc.
3714 Alliance Drive, Suite 105
Greensboro, North Carolina 27407 USA
IDS for ISDN Telephones
jakewink.gif (2520 bytes)
This Web Page created and maintained by the techno-folks at IDS Technologies, Inc.
All rights reserved © 1997, 1998, 1999, 2001