Network Termination Units (NT1)
Lucent Network Termination Units (NT1) units are reliable, compact and versatile. They
provide a direct interface between the switch and an ISDN telephone. The NT1 is a small
box or circuit card located at the users premise at the end of the line coming in from the
service provider. The NT1 converts the 2-wire U-interface from the Central Office Switch
to a 4-wire T-interface for the ISDN device.
The NT1 connects the U-interface to the S/T interface on the phone and performs such
critical functions as performance monitoring, multiplexing and line termination. With a
Mean Time Between Failure Rate well above the norm, Lucent NT1 units are among the most
reliable in the industry.
NT1s are available in a number of models and configurations. These economical, compact
units fit easily in small
spaces and are easy to install.
| NT1B-300 The NT1B-300 is an in-line NT1. It is specifically designed for compatability with the NT1B-310 Rack Module. 2 Status indicators Protection devices on all external interfaces Low power consumption Easily accessible configuration switches Advanced SMD technology Self testing features Built-in multi-point capability |
|
| NT1D-300 The NT1D-300 is a stand-alone 12-fold NT1. |
|
| PR96
PoweRack The PR96 is a premise powering unit that integrates NT1 caging, 48 volt DC power, and battery backup in a single unit for powering ISDN telephones and Lucent NT1P-230 circuit card NT1's. The PR96 will house and power up to 48 NT1P-230 NT1's and provide power for up to 96 phones in a multipoint mode. Distribution is accomplished using standard 50 pin amphenol connectors which eliminate the need to use punchdown blocks. All power lines to the terminals and NT1's are protected by solid state thermal fusing. Additional external battery packs can be added at any time for increased standby time. During extended periods of utility outage the batteries are protected from over-discharge by the built-in low voltage detector and disconnect circuit. Remote monitoring is provided by a contact closure that can be interfaced to a remote alarm unit. |
![]() |
Model # |
Description |
Dimensions |
PR96-8 |
PoweRack with internal 8 AmpHr battery pack
(1 hour holdover) |
19 x 8 x 19 |
Options |
||
RA |
Remote alarm unit |
2.5 x 4 x 1 |
BP8 |
Additional 8 AmpHr battery pack |
19 x 5 x 7 |
NT1P-230 |
Lucent P-230 circuit-card NT1 with
multipoint capability |
|
Technical Specifications
Electrical |
Environmental |
Universal Input (90-265
VAC) |
Operating 0 deg C to +50 deg C |
NT1 Compatibility |
Standards |
Lucent NT1P-230 |
UL 1012, CSA |
![]() |
PR180 The PR180 power and holds (7) NT1D-300 units and (6) NT1P-230 Circuit Cards that provide power for up to 180 ISDN Telephones in a multipoint mode. Specifications:
Dimensions - Width 19 in., Depth 9 in., Height 20 in. |
|
![]() |
![]() |
|
| Model # | Description | Dimensions (W" x D" x H") |
|---|---|---|
| PR180-8 | PoweRack with internal 8 AmpHr battery pack | 19 x 9 x 28 |
Options |
||
| RA | Remote alarm unit | 2.5 x 4 x 1 |
| BP180 | Additional 8 AmpHr battery pack | 19 x 9 x 5.25 |
Technical Specifications
| Electrical | Environmental |
|---|---|
Universal
Input (90-265 VAC) |
Operating 0 deg C to +50 deg C Storage -25 deg C to +60 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
| NT1 Compatibility | Standards |
| Lucent NT1D-300, Lucent NT1P-230 | UL 1012, CSA |
| NT1L-230
NOTE: Manufacturer Discontinued as of March 1998 but some stock still remains available. 2 Status indicators Protection devices on all external interfaces NT1 powering by whichever polarity Low power consumption Advanced SMD technology Self testing features Multi-point with BR 851 adapter |
|
| NT1P-230 The NT1P-230 is a rack mounted NTI. It is specifically designed for compatibility with the NTIM210 rack module or the PR96 / PR180. 2 Status indicators Protection devices on all external interfaces NT1 powering by whichever polarity Low power consumption Easily accessible configuration switches Advanced SMD technology Reset Switch Self testing features Built-in multi-point capability |
|
Rack
Modules
There are several versions of racks to mount the NT1 Units. The NT1B-310 rack houses
NT1B-300 NT1s in multiples of up to 12 per rack. This rack can be installed in an
equipment cabinet or on a wall. It can be ordered with an integrated -48V power supply or
without power.
| NT1B-310 12 Position Mounting Rack | ![]() |
| NT1B-310 24 Position Mounting Rack | ![]() |
The PoweRack 300 Series for Racking and Powering Network Termination Units (NT1B-300)
Lucent Technologies announces the introduction of the PoweRack 300 Series (PR300) for Racking and Powering NT1B-300s. The PR300 PoweRack is a premise powering unit that integrates B300 NT1 rack(s), 48 volt DC power and battery backup in a single unit for powering ISDN telephones and NT1B-300s.
The PR300 is available in four models that house and power 12 to 48 NT1B-300s and provide power for 24 to 96 phones in a multipoint mode. In addition, two of the models are field expandable to allow the user to expand phone configurations by adding an NT1 rack to the unit. The PoweRack 300 can be either wall or rack mounted.
Features:
|
![]() |
| Model | Description | Dimensions (W" x D" x H") |
|---|---|---|
| PR300-24 | PoweRack with 1 NT1 card cage w/ and 2.5 AmpHr battery (2 hour holdover) |
19 x 6 x 12 |
| PR300-48 | PoweRack with 2 NT1 card
cage and 2.5 AmpHr battery (1 hour holdover) |
19 x 6 x 17 |
| PR300-72 | PoweRack with 3 NT1 card
cage and 8 AmpHr battery (2 hour holdover) |
19 x 6 x 30 |
| PR300-96 | PoweRack with 4 NT1 card cage and 8 AmpHr battery (1 hour holdover) |
19 x 6 x 35 |
Options |
||
| RA | Remote alarm unit | 2.5 x 4 x 1 |
| 300R | Additional twelve position NT1 rack | 19 x 5 x 5.25 |
| BP2 | Additional 2.5 AmpHr battery pack (for the PR300-24 and PR300-48) | 19 x 5 x 7 |
| BP8 | Additional 8 AmpHr battery pack (for the PR300-72 and PR300-96) | 19 x 5 x 7 |
| NT1B-300 | Lucent B-300 NT1 with multipoint capability | |
| G-B-300 | Lucent-compatible B-300 type NT1 with multipoint capability | |
Technical Specifications
| Electrical | Environmental |
|---|---|
| Universal Input (90-265 VAC) Frequency 47-440 Hz Output Voltage 42-56 VDC |
Operating 0 deg C to +50 deg C Storage -25 deg C to +60 deg C Humidity 95% non-condensing Optimum battery life will be achieved if the unit is operated at a temperature of 25 deg C. |
| NT1 Compatibility | Standards |
| Lucent NT1B-300 | UL 1012 |
Ordering Information
PoweRack300 Series Specifications/Information
| Ordering Information for Field Installable Options | |
| 300R Additional 12 Position Rack
for the PR300-24 & PR300-72 Comcode 300021102 Also available: 300-U Combination Rack (See below) |
|
| BP2 Additional 2.5AH Battery Pack for PR300-24 & PR300-48 Comcode 300021110 | |
| BP8 Additional 8.0AH Battery Pack for PR300-72 & PR300-96 Comcode 407534734 | |
| Package Contents | Optional 23/25" Mtg Rails for Rack Mts |
| PR300 Series Unit | PR300-24 Model P3-24-3/5 CC 300027851 |
| Mounting for 19 inch rack and wall | PR300-48 Model P3-48-3/5 CC 300027877 |
| Installation Manual | PR300-72 Model P3-72-3/5 CC 300027893 |
| AC input cord 6 feet | PR300-96 Model P3-96-3/5 CC 300027901 |
| Interconnection cables for the Power Supply and the NT1 Racks | 300R rack Model 3R-3/5 CC 300021102 |
| Physical Dimensions (inches) and Weight | Source/Interval |
| PR300-24 (12.3 X 19.0 X 5.8) 15 lbs | PoweRacks KC-GPC (Stock) (KAKA) |
| PR300-48 (17.5 X 19.0 X 5.8) 18 lbs | Optional Items (RPOC) |
| PR300-72 (30.0 X 19.0 X 5.8) 45 lbs | Advertised interval for all is (2) weeks |
| PR300-96 (35.0 X 19.0 X 5.8) 48 lbs | |
| Environmental Temperature | |
| Battery Hold/Power Supply Redundant | Humidity 95% non-condensing |
| PR300-24 2 hour Holdover Redundant PS | Storage -25 Degrees to + 60 Degrees C |
| PR300-48 1 hour Holdover Redundant PS | Operating 0 Degrees C to +50 C |
| PR300-72 2 hour Holdover Non-redundant | |
| PR300-96 1 hour Holdover Non-redundant | |
| Electrical Specifications | |
| Input Voltage 92 132 VAC | |
| Output Voltage 42 56 VDC | |
| Frequency 45 66 Hz | |
| Optional 300-U
Combination Rack This rack offers both Amphenol connection for U Interface in and S/T out as well as RJ45 Patch panel for S/T Interface out. |
![]() |
![]() |
PowerPack 300 PowerPack 300 was introduced to augment the powering of the PowerRack 300 series power racks. The PP300 is an auxiliary power rack that increases the power capabilities of the PR300 by providing an additional 250 watts of capacity for load requirements that exceed the rated capacities of the PR300's. The PP300 simply plugs into an existing PR300 and can be wall or rack mounted. It can also be utilized as a power spare to allow on-line maintenance of the PR300. Use ComCode 300147964 |
Features:
The PR230 PoweRack for NT1P-230 and Amphenol Connection
![]()
|
The PoweRack230 is an uninterruptible power source for ISDN CPE. The PR230 integrates a NT1 card cage, cabling, dc power supply (-48vdc), and a 2.5 amphour battery. The NT1cage hold 12 Lucent NT1-P230 cards, with powering and distribution for up to 24 terminals. Input U and output S/T cabling distribution is by telco standard 25 pair amphenol connectors. S/T outputs provide four output pair for each terminal. Dual rectifiers supply redundant power. NT1s are protected by solid state thermal fusing. The PR230 mounts on the wall or back to back on a 19-inch rack with optional mounting for 23 inch and 25 inch racks. LEDs on the front panel for normal and alarm conditions provide local status of system operation. Remote system monitoring is available by utilizing the PR230s form C relay (RJ11) contact with an optional remote alarm unit. Battery holdover time can be increased by adding external BP2 battery packs. The PR230 comes in two configurations; the PR230-24 for 12 NT1s and 24 multipoint terminals, and the PR230-24 for 24 NT1s and 48 multipoint terminals. The PR230-24 can be field upgraded by adding a separate P230 Cage, the 230R. The PoweRack230 also can provide power and battery holdover to legacy NT1 cages such as the Lucent NT1M-210 cage. |
Electrical Specifications
Mechanical Dimensions
Weight 30 lbs. |
Environmental Temperature
Altitude 10,000 ft. Humidity 95% non condensing Ordering Information
|
You are cordially invited to contact us regarding your ISDN needs and requirements.
Call us: Phone: (336) 299-4409 or Fax us: (336) 856-1342 We gladly acceptIDS Technologies, Inc. 3714 Alliance Drive, Suite 105 Greensboro, North Carolina 27407 USA